x

society for analytical and metrological systems

Search

technical data

housing dimensions

400 x 250 x 160 mm

(W x H x D)

power supply

100 ... 240 Volt /

50 ... 60 Hz

operating voltage

15 V DC, about 20 watts

water hardness range raw water

0.2 mmol/l to 8.9 mmol/l

measuring range carbonate hardness

0.0018 mmol/l to

1.8 mmol/l

threshold value range soft water

0.1 mmol/l to 0.9 mmol/l

Softcontrol Carbonate

monitoring of decarbonization processes

A particular form of water softening is decarbonization, also known as partial softening. Accordingly to the complete water softening, Softcontrol Carbonat monitors the decarbonated water after a decarbonization unit. With exceeding of a given carbonate limit alarm is triggered.

at a glance

  • monitoring of decarbonated water after a decarbonization plant
  • alarm limits from 0,1 mmol/l to 0,9 mmol/l
  • no use of indicators
  • self-monitoring of the device system
  • separate alarm for carbonate hardness and service
  • parameterizable current loop 4 to 20 mA
  • measuring value output via display
  • easy installation and parameterization
  • ecological operation because there is no addition of indicators

advantages

  • high process reliability
  • high efficiency for regeneration
  • continuous measurement as long as water flows
  • automatic data storage and data output via current loop

All further information can be found in our data sheet.

further products